AW氣動(dòng)執(zhí)行器主要特點(diǎn)AW Main features pneumatic actuators
AW系列氣動(dòng)執(zhí)行器分為雙作用式和單作用式(彈簧復(fù)位),兩個(gè)氣體分缸,輸出扭矩大,動(dòng)作靈活平衡;活塞桿鍍硬鉻,有很好的耐磨性;所有滑動(dòng)部件之間配有無油潤滑軸和導(dǎo)向環(huán)以降低摩擦系數(shù),延長使用壽命AW氣動(dòng)執(zhí)行器的U型曲線特性輸出扭矩更適用于大口徑球閥、蝶閥等轉(zhuǎn)角行程閥門的啟、閉和調(diào)節(jié),也可用于其它回轉(zhuǎn)運(yùn)動(dòng)的場合,是實(shí)現(xiàn)工業(yè)管道自動(dòng)化控制的理想裝置。
AW Series pneumatic actuators are divided into double-acting and single acting (spring return), two sub-cylinder gas, the output torque, balanced and flexible movement; hard chromium plated piston rod, good wear resistance; all sliding between parts with or without oil lubrication shaft and guide ring to reduce friction and prolong the life of AW pneumatic actuator output torque characteristic U-shaped curve is more suitable for large-diameter ball valve, butterfly valve stroke corner Kai, closed and regulation, can also be used for other rotary movement of the occasion, is to achieve the ideal of industrial automation control device pipeline.
標(biāo)準(zhǔn)參數(shù)Standard parameters
Air pressure | 0.3Mpa~0.7Mpa(zui大1.0Mpa) |
工作環(huán)境穩(wěn)定 Stable work environment | 基本型Basic:-20℃~+90℃ |
高溫型High temperature:-20℃~+180℃ | |
低溫型Low temperature:-40℃~+90℃ | |
回轉(zhuǎn)角度 Rotation angle | 90° ±5° |
氣源接口 Air Connection | AW13-G1/4 |
AW17-G3/8 | |
AW20~AW40-G1/2 |
型號選擇Model selection
選用時(shí),先確定閥門啟、閉的扭矩,再根本閥門使用的流體介質(zhì),增加安全值。對清潔、潤滑介質(zhì)增加20%
安全值;對水蒸汽或非潤滑介質(zhì)增加25%安全值;非潤滑的干氣介質(zhì)增加60%安全值;非潤滑氣體輸送的顆粒粉料介質(zhì)增加
100%安全值。然后根據(jù)氣源工作壓力,查找雙作用式或單作用式輸出扭矩表,可得到準(zhǔn)確的執(zhí)行器信號。單作用式輸出扭矩
表中,zui小彈簧扭矩即為關(guān)閉閥門時(shí)的扭矩,zui大彈簧扭矩即為打開閥門時(shí)的扭矩。
AW pneumatic actuator used, make sure the valve opens, closing torque, and then do the valve using a fluid medium, added security value. For cleaning, lubricating medium increased by 20%
Security value; of water vapor and non-lubricating medium security value by 25%; non-lubricated dry gas media to increase 60% security value; non-lubricated gas transmission medium to increase the powder particles
100% security value. Then the gas supply pressure of work, find the double-action or single-acting output torque table, available and accurate actuator signal. Single-acting torque
Table, the minimum time to close the valve spring torque is the torque, maximum torque is to open the valve spring torque.
氣動(dòng)執(zhí)行器附件的功能及用途Pneumatic actuator attachment functions and uses of
1、雙作用執(zhí)行器:對閥門開啟和關(guān)閉的兩位式控制。
2、單作用執(zhí)行器(彈簧復(fù)位):在電路、氣路切斷或有故障時(shí),自動(dòng)關(guān)閉閥門。
3、單電控電磁閥:供電時(shí)閥門開啟或關(guān)閉,斷電時(shí)閥門關(guān)閉或打開(可提供防爆型)。
4、雙電控電磁閥:一個(gè)線圈通電時(shí)閥門開啟,另一個(gè)線圈通電閥門關(guān)閉,有記憶功能(可提供防爆型)。
5、限位開關(guān)回訊器:遠(yuǎn)距離傳閥門開或關(guān)位置的信號(可提供防爆型)。
6、電氣定位器:根據(jù)電流信號(4~20MA)的大小對閥門的介質(zhì)流量調(diào)節(jié)控制(可提供防爆型)。
7、氣動(dòng)轉(zhuǎn)換器:將電流信號轉(zhuǎn)換成氣壓信號,與氣動(dòng)定位器配套使用(可提供防爆型)。
8、氣動(dòng)定位器:根據(jù)電流信號(標(biāo)準(zhǔn)0.02~0.1MPA)的大小對閥門的介質(zhì)流量調(diào)節(jié)控制。
9、氣源處理三聯(lián)件:包括空氣減壓閥、過濾器、油霧器。對氣源穩(wěn)定、清潔及運(yùn)動(dòng)部件起潤滑作用。
1, double-acting actuators: valve opening and closing of two control.
2, single-acting actuator (spring return): In the circuit, gas cut off or fails, automatically close the valve.
3, single solenoid valve: open or close the supply valve, the valve closed or open, when power failure (explosion proof available).
4, double solenoid valve: a valve open when the coil is energized, the other coil is energized, the valve closes, with memory function (available in explosion-proof).
5, limit switch back to the hearing: long-distance transmission valve open or closed position signals (explosion proof available).
6, electrical locator: According to the current signal (4 ~ 20MA) the size of the media flow control valve control (available in explosion-proof).
7, pneumatic converter: the current signals into pressure signals, and supporting the use of pneumatic positioner (providing explosion proof).
8, pneumatic positioner: According to the current signal (Standard 0.02 ~ 0.1MPA) the size of the media flow control valve control.
9, Air Treatment FRL: including air relief valve, filter, lubricator. Of the gas source stable, clean and lubricate moving parts.
手操機(jī)構(gòu):自動(dòng)控制在不正常情況下可以手動(dòng)操作閥門的啟閉。
HART institutions: automatic control under normal circumstances you can not manually open and close the valve.
外形尺寸雙作用式Dimension Double-action 型號 L ml H ΦC ΦD f Φd I ΦF p b t AW13 640 201 266 100 132 4-M16 42 37 90 4 12 3.5 AW17 827 270 348 160 190 8-M16 50 60 120 4 14 3.5 AW20 1162 350 425 200 232 8-M16 64 74 140 4 18 4 AW28 1380 460 527 280 318 8-M20 85 100 220 4 25 5 AW35 1860 545 640 300 350 8-M24 105 100 300 10 28×2 6.2
AW40
單作用式外形尺寸Single-acting Dimensions
型號 | L | L1 | ml | H | ΦC | ΦD | F | Φd | I | ΦF | p | b | t | J | G |
AW13S | 858 | 538 | 201 | 266 | 100 | 132 | 4-M16 | 42 | 37 | 80 | 4 | 12 | 3.5 | 32 | 1/4″ |
AW17S | 1090 | 675 | 270 | 348 | 160 | 190 | 8-M16 | 50 | 60 | 120 | 4 | 14 | 3.5 | 66 | 3/8″ |
AW20S | 1430 | 850 | 350 | 425 | 200 | 232 | 8-M16 | 64 | 74 | 140 | 4 | 18 | 4 | 78 | 1/2″ |
AW28S | 1845 | 1155 | 460 | 527 | 280 | 318 | 8-M20 | 85 | 100 | 220 | 4 | 25 | 5 | 84 | 1/2″ |
AW35S | 2605 | 1670 | 545 | 640 | 300 | 350 | 8-M24 | 105 | 100 | 300 | 10 | 28×2 | 6.4 | - | 1/2″ |
雙作用式輸出扭矩(N、M)Double-acting torque
型號規(guī)格 | 氣源壓力Mpa | ||||
0.3 | 0.4 | 0.5 | 0.6 | 0.7 | |
AW13 | 515 | 620 | 770 | 930 | 1080 |
AW17 | 950 | 1270 | 1590 | 1910 | 2230 |
AW20 | 2150 | 2870 | 3580 | 4300 | 5020 |
AW28 | 5150 | 6860 | 8580 | 10300 | 12020 |
AW35 | 10120 | 13500 | 16870 | 20250 | 23620 |
AW40 | 13220 | 17630 | 22040 | 26450 | 30860 |
單作用式輸出扭矩(N、M)Single-acting torque
型號規(guī)格 | 彈簧扭矩 | 氣源壓力Mpa | ||||||
0.4 | 0.5 | 0.6 | ||||||
zui小 | zui大 | zui小 | zui大 | zui小 | zui大 | zui小 | zui大 | |
AW13S | 240 | 450 | 170 | 380 | 320 | 530 | 480 | 690 |
AW17S | 580 | 1230 | 240 | 690 | 360 | 1010 | 680 | 1330 |
AW20S | 1250 | 2440 | 430 | 1620 | 1140 | 2330 | 1860 | 3050 |
AW28S | 3290 | 6050 | 810 | 3570 | 2530 | 5290 | 4250 | 7010 |
AW35S | 5860 | 10480 | 3020 | 7640 | 6390 | 11010 | 9770 | 14390 |
AW40S | 7540 | 15080 | 2550 | 10090 | 6960 | 14500 | 11370 | 18910 |
氣缸容積及重量和耗氣量計(jì)算Cylinder volume and weight and calculation of air consumption
| AW13 | AW17 | AW20 | AW28 | AW35 | AW40 | |
氣缸容量L Cylinder capacity | 雙作用式A+B Double-action A + B | 6.3 | 14.3 | 30.8 | 73 | 148 | 193 |
單作用式B Single-acting B | 3.25 | 7.15 | 15.4 | 36.5 | 74 | 96.5 | |
重量kg Weight | 雙作用式 Double-action | 46 | 79 | 168 | 320 | 600 | 780 |
單作用式 Single-acting | 62 | 112 | 219 | 445 | 835 | 1050 |
注: 雙作用式計(jì)算公式V+(A+B)︱(P+101.2)÷98︱M
單作用式計(jì)算公式V=A︱(P+101.2)÷98︱M
V: 耗氣量NL/min(N升/分)
P: 氣源壓力KpaG(表壓)
M: 活塞每分鐘往復(fù)次數(shù)
A.B:氣缸容量(見表)
將Mpa轉(zhuǎn)換成Kpa乘以1000
Note: Double-action formula V + (A + B) ︱ (P +101.2) ÷ 98 ︱ M
Single-acting formula V = A ︱ (P +101.2) ÷ 98 ︱ M
V: Air Consumption NL / min (N L / min)
P: Air pressure KpaG (gauge)
M: number of reciprocating piston per minute
A.B: cylinder capacity (see table)
Will Mpa multiplied by 1000 to convert Kpa
安裝使用與維護(hù)Installation and maintenance
1、氣動(dòng)執(zhí)行器可與閥門直接連接,也可通過支架和接頭與閥門安裝連接。連接緊固件不得松動(dòng)。
2、保證執(zhí)行器輸出軸與閥桿安裝的同軸度,并轉(zhuǎn)動(dòng)靈活,無爬行現(xiàn)象。
3、連接管道、接頭、附件等應(yīng)清潔干凈。
4、電磁閥排期口始終向下,當(dāng)向上或水平時(shí),應(yīng)連接彎管,使排氣口向下。
5、調(diào)試前應(yīng)確定空氣管道通暢,氣壓、電壓、信號等符合要求。
6、壓縮空氣應(yīng)經(jīng)過過濾、干燥、露點(diǎn)-15℃以下要除濕。
7、調(diào)試時(shí)電磁閥應(yīng)開到自動(dòng)位置。
8、氣動(dòng)操作時(shí),應(yīng)斷開手動(dòng)裝置,手動(dòng)操作時(shí)應(yīng)斷開氣動(dòng)裝置。
9、執(zhí)行器上安裝的各種附件,應(yīng)分別參照使用說明進(jìn)行調(diào)試、
10、正常工作情況下每月檢查一次,每年檢修一次。
1, the pneumatic actuator can be directly connected with the valve, brackets and fittings can also be connected with the valve installation. Fasteners must not loose connection.
2, to ensure that the actuator output shaft coaxial with the valve stem is installed, and turn the flexible non-crawling phenomenon.
3, connecting pipes, fittings, accessories, etc. should be clean.
4, solenoid valve scheduled port is always down, when the level up or when the pipe should be connected so that the exhaust downward.
5, testing should be determined before the channel clear air, pressure, voltage, signals meet the requirements.
6, compressed air should be filtered, dried, dew point -15 ℃ to dehumidify the following.
7, solenoid valve should open when debugging to the automatic position.
8, pneumatic operation, the device should be disconnected manually, manually operated pneumatic devices should be disconnected.
9, the actuator is installed on a variety of accessories, should be separay described with reference to use for debugging,
10, under normal operating conditions once a month, once a year overhaul.