化工儀器網(wǎng)>產(chǎn)品展廳>行業(yè)專用儀器及設備>其它行業(yè)專用儀器>其它專用儀器>Bante900/901/902/903 Bante900/901/902/903多參數(shù)水質(zhì)測量儀
Bante900/901/902/903 Bante900/901/902/903多參數(shù)水質(zhì)測量儀
- 公司名稱 上海民儀電子有限公司
- 品牌
- 型號 Bante900/901/902/903
- 產(chǎn)地 上海
- 廠商性質(zhì) 生產(chǎn)廠家
- 更新時間 2024/8/15 15:04:12
- 訪問次數(shù) 2432
聯(lián)系方式:蘭亞13917179551 查看聯(lián)系方式
聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!
焊臺:吸煙儀:熔錫爐:熱風槍:膠紙機:螺絲機:點膠機:扭力測試儀:硬度計:離子風機:離子風槍:扭力扳手:推拉力計:靜電測試儀:塵埃粒子計數(shù)器:靜電手指套:放大鏡:顯微鏡:電子秤:溫度計:萬用表:LCR電橋:風速儀:頻閃儀:轉(zhuǎn)速表:噪音計:安規(guī)測試儀:耐壓測試儀:照度計:電動螺絲刀:超聲波測厚儀:涂層測厚儀:真空干燥箱:防潮箱:示波器:直流電源:電源供應器:信號發(fā)生器:探傷儀:檢漏儀:離子計:比色儀:色譜儀:
Bante90系列多參數(shù)水質(zhì)測量儀包含四款型號, 產(chǎn)品適用于測
量液體的pH, 氧化還原電位(ORP), 離子濃度, 電導率, 溶解性
總固體( TDS ), 鹽度, 電阻率, 溶解氧( DO )等水質(zhì)參數(shù)。.
Bante900/901/902/903多參數(shù)水質(zhì)測量儀儀器功能:
● Bante900: pH, ORP, 離子, 電導率, TDS, 鹽度, 電阻率, 溶解氧
● Bante901: pH, ORP, 離子, 電導率, TDS, 鹽度, 電阻率
● Bante902: pH, ORP, 溶解氧
● Bante903: 電導率, TDS, 鹽度, 電阻率, 溶解氧
Bante900/901/902/903多參數(shù)水質(zhì)測量儀自動校準:
儀器具有多點按鍵校準功能, 校準時儀器自動提示您需要使
用的校準液類型, 您只需按提示將電極傳感器浸入相應的校
準液中, 按ENTER鍵, 儀器即會自動校準。
自動識別標準緩沖液:
校準時, 如果您錯誤使用標準緩沖液或者使用嚴重變質(zhì)的校
準液, Bante90系列將自動報警并提示ERROR。
多模式離子測量:
Bante 900內(nèi)置多種離子測量模式, 按ENTER鍵, 儀器依次轉(zhuǎn)換
離子濃度測量模式(pX, mg/L, ppm)。
相對mV測量功能:
在ORP 測量模式, 儀器具有相對mV測量功能, 使用氧化還原
電位校準液, 您可以修正測量誤差以提升ORP 測量精度。.
自動量程轉(zhuǎn)換:
測量電導率或TDS 時, 儀器具有自動量程轉(zhuǎn)換功能。當電極
傳感器浸入樣品后, Bante 90系列將自動掃描當前測量值并
轉(zhuǎn)換量程, 儀器將以精確的分辯率顯示終點測量值。.
Model | Bante900 | Bante901 | Bante902 | Bante903 |
pH測量范圍 | -2.000~16.000pH | ● | ● | ● |
pH測量精度 | ±0.002pH | ● | ● | ● |
pH校準點 | 2點 | ● | ● | ● |
使用校準液 | pH4.00/6.86/9.18 或 pH4.01/7.00/10.01 | ● | ● | ● |
溫度補償范圍 | 0~100oC | ● | ● | ● |
ORP測量范圍 | -1999.9~1999.9mV | ● | ● | ● |
ORP測量精度 | ±0.2mV | ● | ● | ● |
離子濃度測量范圍 | 0~19999ppm (基于離子電極量程) | ● | --- | --- |
離子濃度測量精度 | ±0.5% F.S (一介離子), ±1% F.S (二介離子) | ● | --- | --- |
離子校準點 | 2~5點 | ● | --- | --- |
使用校準液 | 10-2, 10-3, 10-4, 10-5, 10-6mol/L | ● | --- | --- |
溫度補償范圍 | 0~100oC | ● | --- | --- |
電導率測量范圍 | 0~200mS/cm | ● | ● | --- |
電導率測量精度 | ±0.5% F.S | ● | ● | --- |
電導率校準點 | 1點 | ● | ● | --- |
可選電極常數(shù) | K=0.1, 1, 10 | ● | ● | --- |
溫度補償系數(shù) | 0~3.9%每oC | ● | ● | --- |
溫度補償范圍 | 0~50oC | ● | ● | --- |
TDS測量范圍 | 0~Max.200ppt | ● | ● | --- |
TDS測量精度 | ±1% F.S | ● | ● | --- |
TDS轉(zhuǎn)換系數(shù) | 0.01~1.00, 默認值0.67 | ● | ● | --- |
鹽度測量范圍 | 0.00~50.0ppt | ● | ● | --- |
鹽度測量精度 | ±1% F.S | ● | ● | --- |
電阻率測量范圍 | 0~100MΩ | ● | ● | --- |
電阻率測量精度 | ±1% F.S | ● | ● | --- |
溶解氧測量范圍 | 0.00~20.00mg/L (ppm) | ● | --- | ● |
溶解氧測量精度 | ±0.3mg/L | ● | --- | ● |
% 飽和度量程 | 0~200.0% | ● | --- | ● |
% 飽和度精度 | ±5.00% | ● | --- | ● |
校準點 | 1或2點 | ● | --- | ● |
鹽度補償范圍 | 0~35g/L | ● | --- | ● |
大氣壓力設定 | 450~850mmHg, 60.0~112.5kPa | ● | --- | ● |
溫度補償范圍 | 0~40oC | ● | --- | ● |
溫度測量范圍 | 0~100oC, 32~212oF | ● | ● | ● |
溫度測量精度 | ±0.3oC, ±0.5oF | ● | ● | ● |
儲存數(shù)據(jù) | 99組 | ● | ● | ● |
通訊輸出 | USB標準 | ● | ● | ● |
電源類型 | 9V/350mA電源適配器 | ● | ● | ● |
外形尺寸 | 210(L)×188(W)×60(H)mm | ● | ● | ● |